Leonardo Mechanograph® GRFP PRO

The standard model for sports and research. Felxible use for staionary or mobile application with two seperate platforms which can be positioned as needed. Dynamic measurement of ground reaction forces including side-differences. Spatial resolution e.g. for balance tests.

Price: On request. Please contact us for your personal offer.
Please select your country or contact the appropriate distributor to ensure product availability.

SKU: 8N600701, 8N600702 Category:

The standard model for sports and research

Flexible and mobile version for use in sports, research and advanced users.

Dynamic measurement of ground reaction forces forces with respect to spatial resolution. Easy to use and to instruct, fast application and at the same time high reproducibility due to the utilised everyday motions. Applicable in any age group (reference data from 3 to 99 years included). Typical measurement duration about 1 minute per test (about 3 minutes for standard functional assessment consisting of 4 tests).The test procedures include different jumps for the analysis of individual anaerobic peak power, maximum voluntary muscular force and movement asymmetries. The 2-platform design also allowes to place the two froce plates at a distance e.g. for wide push-ups or for force Monitoring during weight lifting. Various balance tests are supported. The split platform allows a quantification of asymmetries of physiological movements. Included in delivery are the measurement platform Leonardo Mechanograph GRFP PRO and the analysis software Leonardo Mechanography BAS. Optionally available are grip-force sensor, Frame and a measurement PC or laptop with software preinstalled.

Producer

Novotec Medical GmbH

Medical device

No

Dimensions platform

(2x) 330 x 660 x 70 mm

Dimensions total (l/w/h)

660 x 660 x 70 mm

Weight Platform

15 kg

Weight total

30 kg

Number of Sensors

(2x) 4

Sample rate

bis zu/up to 2000 Hz

Resolution AD-converter

16 bit

max. force per sensor

ca. 2 kN

Interface to PC

USB 2.0, USB 3.0

Analysis software

Leonardo Mechanography BAS v4.4

Type No.

8N600701, 8N600702

Seperated platform for left/right leg (side-differences)

Yes

Supported Test Types and Assessments

s2LJ, m1LH, m2LJ, CRT, BAss, DJ, LT, RT, TRT, BT, TpTs, TpTc, ST, LST, IF (depending on software type)

Included in delivery